导航:全球石油化工网 >> 产品频道 >> 仪器仪表 >> 光学仪器 >> 分光仪
  • 广州易测仪器有限公司
  • 化工币: 100
  • 诚信指数:20   诚信等级:诚信等级:二星级
  • 荣誉证书:0 项
  • 联系人:
  • 电话:86-020-62807049   13068888611
  • 邮箱:
  • 公司地址:中国 广东 广州市 天河区燕岭路123号建设大厦1216室
  • (联系时,请一定说明是从全球石油化工网看到的)
  • 最近供应 | 诚信档案 | 企业介绍
该公司还有8条同类“分光仪”供应商机
详细信息
 类型:   台式分光仪  测量精度:   台湾 ((mm))
 外形尺寸:   ET-8001 ((mm))   

Photometric mode is a simple measurement mode of Absorbance (ABS) or Transmittance (%T) at fixed single or multiple wavelengths.   Spectrum mode provides spectral measurement at user-defined wavelength range (between 200nm and 1000nm, low & high limits of measurement result, and scanning speed (at 100-5000nm/min) . The measured spectra can be saved ,zoomed, tracked ,and picked of peaks and valleys for various data manipulation. ? Time Scan mode is to perform scanning of a sample at a fixed wavelength for user-defined time. Functions as to save, to zoom, to track, and to search peaks and valleys of the measured spectra as also featured. Kinetic mode provides application software for measurement of enzyme activity at fixed wavelength. Optional temperature control is available upon request. Quantitative mode measures and determines the concentration of an unknown sample at a specific wavelength with calibration curve created form standards. SP- 8001 incorporates a universal sample compartment that accommodates a complete line of accessories - single cell holder, single cell holder adapted for water circulation temperature control unit (optional) , 6-cell holder (optional) , flow-cell assembly (optional) , etc. Sample compartment versatile 10-100mm pathlength cuvette and 10-25mm diameter test tube. Change of cell chamber is quick and simple. Specifications CAT. No. ET-8001 Wavelength Range 波长范围 190-1100nm Bandwidth Pass光谱带宽 ∝2nm Wavelength Accuracy 光谱精度 ±0.5nm Monochromator Dual Detectors/ Split-Beam Wavelength Repeatability 波长重复性 ±0.2nm Photometric Range测量范围 -0.300 ~ 3,000 Abs Photometric Accuracy 测量精度 ±0.005Abs at 1.000Abs with ASTM method Stability漂移 Drifting 0.0003Abs /hr at 500nm after 1 hour warm-up Baseline Flatness基线 ±0.002Abs Stray Light杂散光 < 0.05 % at 340nm & 220nm by ASTM method Light Source光源 Deuterium lamp (UV range) & halogen lamp (Vis range) Source lamp change灯转换 Automatic自动 Detector检测器 Si photodiode Wavelength scan speed扫描速度 100~5000nm/min (user-programmable) Pathlength Variable at 10-100mm Display显示 Backlit LCD-adjustable contrast Interface Serial & parallel Power电源 AC 100/120/220/240V 50/60Hz Dimension (mm)尺寸 506(W) x 430(D) x 220(H) Weight重量 18kgs
其它相关产品
相关搜索推荐
找不到合适信息?

留下您的采购意愿,我们将帮您推荐诚信供应商!
注:此功能仅对企业用户开放,如果您不是企业用户请点击注册.

免责说明
本网所展现的公司信息、产品信息及其他相关信息均由企业自行提供,信息的真实性、准确性和合法性由商铺所属企业完全负责。全球石油化工网对此不承担任何保证责任。
关于我们 | 会员服务 | 电子样本 | 邮件营销 | 网站地图 | 诚聘英才 | 意见反馈
Copyright @ 2012 CIPPE.NET Inc All Rights Reserved 全球石油化工网 版权所有
京ICP证120803号 京ICP备05086866号-8 京公网安备110105018350